All Techniques (5) Nucleic Acid Quantification (9) Lipid Transfection (8) End-point PCR Primers (9) Cell Culture (Contamination) (7) PCR (Sigma Guide) (12) Flow Cytometry (Controls) (8) PCR / qPCR Plastics (9) PCR (Invitrogen Guide) (8) Cell Culture (Precipitates) (6) Cell Culture (Cell Death) (8) ELISA (Sigma Guide) (6) PCR / RT-PCR Amplification Problems (5) Flow Cytometry (Paraformaldehyde Fixation) (14) Flow Cytometry (Sample Considerations) (14) ELISA (R&D Guide) (10) Western Blot Immunodetection (19) Flow Cytometry (CST Guide) (8) Immunohistochemistry (CST Guide) (14) Immunoprecipitation (CST Guide) (14) ChIP (CST Guide) (8) ELISA Development (9) Western Blot (Sigma Protocol) (8) IP-Western Blot (6) Western Blot (CST Guide) (8) Flow Cytometry (Fixation Buffers) (7) Flow Cytometry (Isotype Controls) (7) Flow Cytometry (Fixation & Permeabilization) (9) Flow Cytometry (Fc Blocking) (7) Flow Cytometry (Compensation) (7) Flow Cytometry (Autofluorescence) (7) Flow Cytometry (Troubleshooting) (8) Tissue Imaging (Autofluorescence) (9) ELISPOT (8) Immunoprecipitation (Protein Obstruction) (1) Immunoprecipitation (No Protein Detected) (5) Immunoprecipitation (High Background) (8) Immunoprecipitation (High Antibody Elution) (1) Immunohistochemistry (No Staining) (9) Immunohistochemistry (High Background) (9) ChIP (PCR Amplification Problems) (4) ChIP (Low Signal) (8) ChIP (Low Resolution with High Background) (6) ChIP (High Background) (1) Western Blot (Blue Background) (1) Western Blot (Unusual Gel Band Appearance) (3) Western Blot (Unexpected Multiple Bands) (7) Western Blot (Misshapen / Uneven Bands) (5) Western Blot (Bands at Wrong MW) (5) Western Blot (Detection Problems) (7) Western Blot (Weak / No Signal) (6) ELISA (Standard Curve Fit Problems) (6) ELISA (Inconsistent Results / High CV) (6) ELISA (High Background) (8) ELISA (Signal Problems) (11) ELISA (Competitive) (18) Cell-free DNA Extraction (8) Bacterial rRNA Depletion (4) RNA Depletion for RNA-seq (7) LAMP (Loop-mediated Isothermal Amplification) (7) HMW DNA Extraction (Monarch) (7) NGS Library Preparation (NEBNext Ultra II) (7) RNA Cleanup (4) DNA Cleanup & Plasmid Purification (7) PCR (Polymerase Chain Reaction) (26) Restriction Enzyme Digest (13) Western Blot (9) Immunohistochemistry (IHC) (6) Colony Formation Assay (10) Transwell Migration / Invasion Assay (5) qPCR (RT-qPCR) (5) Transfection (8) Plasmid Construction (1) Sanger Sequencing (2) Plasmid Mini-prep (1) Plasmid Construction (Double Digest) (1) Protein Extraction (4) Transfection (Co-transfection) (1) Transfection (siRNA Knockdown) (1) CCK-8 Cell Viability Assay (5) Wound Healing Assay (5)
qPCR (RT-qPCR) severe

Reference gene is unstable — normalization fails

Reference gene Ct varies > 1 cycle between samples; trend of reference vs target gene disagrees; normalization gives strange results.

💡 4 causes ✓ 4 fixes
qPCR (RT-qPCR) severe

Abnormal melt curve (multiple peaks or shoulder)

Melt curve shows multiple peaks or a shoulder, Tm does not match expectation, gel shows multiple bands.

💡 5 causes ✓ 5 fixes
qPCR (RT-qPCR) severe

Poor Ct reproducibility — high within-group variability

Technical replicates of the same sample have SD > 0.5 cycles; standard curve linearity is poor; loading order influences results.

💡 5 causes ✓ 5 fixes
qPCR (RT-qPCR) moderate

Atypical amplification curves (not the canonical S-shape)

Curves cross threshold but are not the canonical sigmoidal shape — may have weird plateaus, early plateaus, or noisy baselines.

💡 5 causes ✓ 5 fixes
qPCR (RT-qPCR) critical

No amplification — Ct value missing or > 40

Amplification plot is flat for both target and reference; software reports "no Ct" or Ct > 40 even for positive controls.

💡 5 causes ✓ 5 fixes