Failure Case Library

Real lab failures, root causes, and fixes — curated and bilingually annotated by our team.

All Techniques (8) Nucleic Acid Quantification (9) Lipid Transfection (8) End-point PCR Primers (9) Cell Culture (Contamination) (7) PCR (Sigma Guide) (12) Flow Cytometry (Controls) (8) PCR / qPCR Plastics (9) PCR (Invitrogen Guide) (8) Cell Culture (Precipitates) (6) Cell Culture (Cell Death) (8) ELISA (Sigma Guide) (6) PCR / RT-PCR Amplification Problems (5) Flow Cytometry (Paraformaldehyde Fixation) (14) Flow Cytometry (Sample Considerations) (14) ELISA (R&D Guide) (10) Western Blot Immunodetection (19) Flow Cytometry (CST Guide) (8) Immunohistochemistry (CST Guide) (14) Immunoprecipitation (CST Guide) (14) ChIP (CST Guide) (8) ELISA Development (9) Western Blot (Sigma Protocol) (8) IP-Western Blot (6) Western Blot (CST Guide) (8) Flow Cytometry (Fixation Buffers) (7) Flow Cytometry (Isotype Controls) (7) Flow Cytometry (Fixation & Permeabilization) (9) Flow Cytometry (Fc Blocking) (7) Flow Cytometry (Compensation) (7) Flow Cytometry (Autofluorescence) (7) Flow Cytometry (Troubleshooting) (8) Tissue Imaging (Autofluorescence) (9) ELISPOT (8) Immunoprecipitation (Protein Obstruction) (1) Immunoprecipitation (No Protein Detected) (5) Immunoprecipitation (High Background) (8) Immunoprecipitation (High Antibody Elution) (1) Immunohistochemistry (No Staining) (9) Immunohistochemistry (High Background) (9) ChIP (PCR Amplification Problems) (4) ChIP (Low Signal) (8) ChIP (Low Resolution with High Background) (6) ChIP (High Background) (1) Western Blot (Blue Background) (1) Western Blot (Unusual Gel Band Appearance) (3) Western Blot (Unexpected Multiple Bands) (7) Western Blot (Misshapen / Uneven Bands) (5) Western Blot (Bands at Wrong MW) (5) Western Blot (Detection Problems) (7) Western Blot (Weak / No Signal) (6) ELISA (Standard Curve Fit Problems) (6) ELISA (Inconsistent Results / High CV) (6) ELISA (High Background) (8) ELISA (Signal Problems) (11) ELISA (Competitive) (18) Cell-free DNA Extraction (8) Bacterial rRNA Depletion (4) RNA Depletion for RNA-seq (7) LAMP (Loop-mediated Isothermal Amplification) (7) HMW DNA Extraction (Monarch) (7) NGS Library Preparation (NEBNext Ultra II) (7) RNA Cleanup (4) DNA Cleanup & Plasmid Purification (7) PCR (Polymerase Chain Reaction) (26) Restriction Enzyme Digest (13) Western Blot (9) Immunohistochemistry (IHC) (6) Colony Formation Assay (10) Transwell Migration / Invasion Assay (5) qPCR (RT-qPCR) (5) Transfection (8) Plasmid Construction (1) Sanger Sequencing (2) Plasmid Mini-prep (1) Plasmid Construction (Double Digest) (1) Protein Extraction (4) Transfection (Co-transfection) (1) Transfection (siRNA Knockdown) (1) CCK-8 Cell Viability Assay (5) Wound Healing Assay (5)
ChIP (CST Guide) severe

Equivalent Signal in Negative IgG and Positive H3 Controls

Quantity of PCR product in negative control Rabbit IgG-IP equals that in positive control Histone H3-IP, indicating high non-specific binding or PCR over-amplification.

💡 5 causes ✓ 5 fixes
ChIP (CST Guide) critical

No Product in Histone H3 Positive Control IP

Positive control Histone H3-IP with RPL30 primer set produces no PCR product, indicating fundamental problems with IP procedure or elution.

💡 4 causes ✓ 4 fixes
ChIP (CST Guide) critical

No or Minimal PCR Product in Input Control

Input chromatin PCR reactions produce no product or very little product, indicating problems with DNA quantity, PCR conditions, or primer design.

💡 5 causes ✓ 5 fixes
ChIP (CST Guide) severe

Chromatin Under-Fragmentation with Excessive Large Fragments

Chromatin fragments are too large (>900 bp for enzymatic, >1 kb for sonication), leading to increased background signal and lower resolution in ChIP results.

💡 4 causes ✓ 4 fixes
ChIP (CST Guide) severe

Chromatin Over-Fragmentation to Mono-Nucleosome Length

More than 80% of DNA fragments are shorter than 500 bp, resulting in diminished PCR signal especially for amplicons >150 bp, and potential disruption of chromatin integrity and antibody epitopes.

💡 4 causes ✓ 4 fixes
ChIP (CST Guide) severe

No Product in Experimental Antibody IP

Experimental antibody-IP PCR reaction produces no product while positive control H3-IP works, indicating antibody-specific or target-specific issues.

💡 5 causes ✓ 5 fixes
ChIP (CST Guide) severe

Fragmented Chromatin Concentration Below Required Threshold

DNA concentration of chromatin preparation is insufficient for ChIP, falling below the recommended 50 µg/ml or unable to provide 5-10 µg per IP reaction.

💡 4 causes ✓ 4 fixes
ChIP (CST Guide) severe

Low Fragmented Chromatin Concentration

DNA concentration of fragmented chromatin preparation is below expected ranges (e.g., <100 µg/ml for HeLa cells, <20 µg/ml for brain tissue). Insufficient material for recommended 5-10 µg chromatin per IP reaction.

💡 4 causes ✓ 5 fixes