Home Immunology Zhejiang University Senior's Flow Cytometry Hands-On Tutorial
Immunology Bilibili (China-Accessible Mirrors)

Zhejiang University Senior's Flow Cytometry Hands-On Tutorial

🚨 Failure Case Library (14) + Submit your own case

severe
High Background Staining from Non-Specific Fc Binding
Flow cytometry data shows elevated background fluorescence and false-positive signals, particularly in populations with high Fc receptor expression (monocytes, macrophages, dendritic cells, B cells, NK cells). Antibodies bind to cells lacking the target antigen.
💡 4 · ✓ 5
severe
Surface Receptor Downregulation After Temperature or Stimulation
Loss of surface staining intensity or complete absence of expected surface markers (chemokine receptors CCR7, cytokine receptors CD115/M-CSFR, TCR/CD3 complex) after exposure to non-optimal temperatures or antibody/cytokine stimulation, leading to underestimation of target population frequencies.
💡 4 · ✓ 4
severe
Weak or No Fluorescence Signal Detected
Flow cytometer detects very weak or absent fluorescence from stained cells. Expected positive population shows minimal or no signal separation from unstained controls.
💡 6 · ✓ 6
severe
Rare Cell Population Incorrectly Gated or Missed
Target rare immune cell subsets (e.g., dendritic cells, innate lymphoid cells, hematopoietic progenitors) appear overestimated or masked by abundant terminally differentiated cells. Gating on single markers yields incorrect population percentages (e.g., 4.5% vs. true 1.2% DCs).
💡 4 · ✓ 4
severe
Non-specific Antibody Binding via Fc Receptors
Elevated background staining on myeloid cells (monocytes, macrophages, dendritic cells, granulocytes) in bone marrow, blood, spleen, or in vitro myeloid cultures. False-positive signals not blocked by standard washing.
💡 4 · ✓ 5
severe
Nonspecific Antibody Binding via Fcγ Receptors
Elevated false-positive staining observed in myeloid-enriched samples (bone marrow, blood, spleen, in vitro myeloid differentiation cultures) due to antibody Fc region binding to Fcγ receptors on monocytes, macrophages, dendritic cells, and granulocytes.
💡 4 · ✓ 4
severe
Antibody Epitope Destruction by Enzymatic Digestion
Antibody fails to recognize target antigen on cells after enzymatic tissue dissociation or adherent cell detachment, resulting in absent or dramatically reduced staining intensity for markers like cadherins despite confirmed gene/protein expression by other methods.
💡 4 · ✓ 4
severe
Rare Cell Populations Overwhelmed by Abundant Cells
Target rare immune cell populations (e.g., dendritic cells, innate lymphoid cells, hematopoietic progenitors) cannot be adequately resolved or quantified due to overwhelming signals from abundant terminally differentiated cells in lymphoid tissues or non-lymphoid tissues.
💡 4 · ✓ 4
moderate
Inadequate Controls for Fc Blocking Verification
Inability to distinguish whether observed staining is specific or due to incomplete Fc blocking. Uncertainty about blocking efficacy and data interpretation.
💡 4 · ✓ 5
moderate
Elevated Autofluorescence in Myeloid and Granular Cells
High background fluorescence detected in shorter wavelength channels (BV421, FITC, PE), particularly in larger granular cells such as monocytes, neutrophils, eosinophils, macrophages, and dendritic cells, compromising signal-to-noise ratio for true positive events.
💡 4 · ✓ 4
moderate
Antibody Epitope Alteration by Fixation
Surface marker staining intensity decreases or disappears when antibodies are applied after cell fixation, or intracellular targets remain undetectable despite using fixation/permeabilization buffers, indicating epitope conformational changes or masking.
💡 4 · ✓ 4
moderate
Incomplete Red Blood Cell Lysis in Whole Blood
Red blood cell debris persists in whole blood samples after lysis protocol, causing high background and interfering with target cell population analysis.
💡 3 · ✓ 3
moderate
Autofluorescence Interferes with Detection Channels
High background fluorescence observed in BV421, FITC, and PE channels, particularly with myeloid cells (monocytes, macrophages, neutrophils, eosinophils). Positive signal difficult to distinguish from cellular autofluorescence.
💡 4 · ✓ 5
minor
Fc Blocking Reagent Storage and Stability Problems
Progressive decline in Fc blocking efficacy over time with the same reagent lot. Previously effective blocking protocol shows increasing background in recent experiments.
💡 5 · ✓ 6