🚨 Failure Case Library (15) + Submit your own case

critical
Complete Absence of Signal in Western Blot
No bands are visible on the Western blot membrane or film. Complete absence of signal despite confirmed protein loading and transfer.
💡 6 · ✓ 6
severe
No Bands with Recombinant or Overexpressed Protein
No bands appear when testing recombinant protein or overexpression lysate, despite expected high protein levels, indicating structural or epitope accessibility issues.
💡 3 · ✓ 3
severe
Non-Specific Bands from Antibody Cross-Reactivity
Multiple bands appear at unexpected molecular weights that do not correspond to known forms of the target protein. These bands may vary in intensity between experiments and do not correlate with expected protein expression patterns.
💡 5 · ✓ 5
severe
Additional or Wrong-Sized Bands Appearing
Unexpected bands appear at molecular weights different from target protein. Multiple bands present instead of single expected band, or band appears at incorrect size.
💡 5 · ✓ 5
severe
Weak or Diminished Western Blot Signal
Expected protein bands appear faint or barely visible on film or imaging system, even after extended exposure times.
💡 6 · ✓ 6
severe
Large Error Bars in Quantitative Western Blotting
Replicate Western blots show high variability in band intensity measurements. Coefficient of variation exceeds acceptable limits (>15-20%) making quantitative comparisons unreliable.
💡 4 · ✓ 4
severe
Large Error Bars in Quantitative Western Blotting
Quantitative measurements show high variability between replicates. Large error bars or standard deviations prevent statistical significance despite apparent differences.
💡 4 · ✓ 4
moderate
Membrane Type Contributing to High Background
Persistent high background signal related to membrane choice, particularly when using PVDF membranes which generally produce more background than nitrocellulose.
💡 3 · ✓ 3
moderate
Altered Band Pattern from Excessive Cell Passage
Band patterns differ from expected or previously observed results when using cell lines that have been maintained in culture for extended periods. Multiple unexpected bands or altered expression levels appear compared to earlier passages.
💡 4 · ✓ 5
moderate
High Background in Rapid Immunodetection Protocol
When using rapid immunodetection methods, membrane shows elevated background specific to fast protocols. Issue not present with standard overnight protocols.
💡 5 · ✓ 5
moderate
High Background Signal Across Membrane
Excessive background signal across the membrane obscures specific bands, caused by non-specific antibody binding, inadequate blocking, or improper handling.
💡 6 · ✓ 6
moderate
Extra Bands at 2× or 3× Expected Molecular Weight
Additional bands appear at molecular weights that are integer multiples (2×, 3×, or higher) of the expected target protein size, indicating oligomeric forms. These higher molecular weight bands suggest incomplete protein denaturation.
💡 4 · ✓ 4
moderate
Non-Specific Signal from Insoluble Protein in Well or Dye Front
Strong signal appears at the top of the gel (in or near the loading well) or at the bottom (dye front), unrelated to the expected molecular weight of the target protein. This is especially common for very high molecular weight proteins (>250 kDa).
💡 4 · ✓ 5
minor
Uneven or Irregular Blot Appearance
Membrane shows fingerprints, fold marks, or forceps imprints creating irregular patterns. Uneven signal distribution not related to protein bands.
💡 4 · ✓ 4
minor
Uneven or Distorted Blot Pattern
Membrane shows irregular signal distribution with visible fingerprints, fold marks, or forceps imprints. Signal intensity varies across membrane surface in non-biological pattern.
💡 4 · ✓ 4
💬 Comments coming soon